MANUFACTURERS OF COPPER NICKEL PIPE, FITTING AND FLANGE PACKAGES FOR SHIPBUILDING AND OFFSHORE INDUSTRY

Applications


Click here for Ship Building and Repair

Click here for Offshore Units

Click here for Desalination

Click here for Power Generation

Images provided by courtesy of the Copper Development Association Inc. (U.S.A.)
To have more information about Copper applications : » www.copper.org «


NITON 10 have an excellent behaviour when exposed to all forms of marine corrosion.
This property is mainly due to the fact that the alloy prevents dissolution by forming a very strong protective surface film.

NITON 10 and NITON 30 possible factors of corrosion

Corrosive environment Probable corrosion Behaviour in service
Clean sea water circulation at a velocity of up to 1 m/s Uniform or general 0.0025 - 0.025 mm/year
Clean sea water circulation at a velocity of up to 3.5 m/s* : NITON 10 and 4.5 m/s* : NITON 30 Impact corrosion Satisfactory
Polluted sea water General corrosion and accelerated pitting corrosion Less resistance
Deposits accumulated at the surface Local attack Generally good
Corrosion + stress Stress corrosion Very resistant
* the local speeds resulting from obstructions can be higher

Behaviour of NITON 10 and NITON 30 in the presence of sea water,
brine and sea atmospheric exposures

Type of corrosion Behaviour
General corrosion Slightly sensitive to this type of corrosion
Corrosion rate is less than 25 µ/year
Pitting corrosion Insensitive to this type of attack
Penetration rate less than 25/130 µ/year
Selective corrosion Insensitive
Do not lose the alloying component like brasses and aluminium bronzes
Stress corrosion Never affected by this type of corrosion
Fouling corrosion Insensitive
Even at a low circulation speed, and although not affected by general corrosion, perfectly resist to the build-up of marine organisms
Corrosion-Erosion
(impingement attack)
Very slightly sensitive
The addition of an optimum quantity of iron improves the nature of the protective film and makes the alloy very resistant to this type of agression
Galvanic corrosion Insensitive in the presence of other copper based metals
With a dissolution potential of 200 mv/ECS in sea water, NITON 10 is compatible with all other copper based metals

Behaviour of NITON 10 and NITON 30 in other environments

- good resistance in an ammoniacal environment
- the behaviour of copper nickel in the presence of crude petroleum is correct in the vapour phase, with however, the risk of the protective film being destroyed

Resistance of NITON 10 to fire

Tests of resistance to fire have been made in simulating the service conditions of a pipeline during an offshore fire : piping empty - during 5 minutes - at 700 degrees Celsius, partly in the flame, then 15 minutes on water (with the start of the sprinklers).
They have shown the total reliability of NITON 10 : no rupture of the weld or of the brazing, no leakage, no permanent deformation.
After the end of the fire, the piping in NITON 10 has needed no replacement.